SPECIFICATIONS

Electrical

Power Output 10 W minimum (2)
Gain (at rated power out) 30 dB minimum (3)
Duty CW
Noise Figure 30 dB typical,5 dB maximum
VSWR 2.5:1 maximum


Mechanical

Construction metal ceramic
Cooling conduction
Focusing PPM
Weight 3 pounds (1.4 kilograms) maximum
Connectors (input & output) SMA


Environmental

Temperature (baseplate) 85°C maximum
Altitude (non-operating) 50,000 feet (15,250 meters) maximum


The TWT is rugged in design and in general, will meet the requirements of MIL-E-5400.  Contact DynamicWave for specific details.

Warranty

One full year regardless of the hours of operation.

 