Controls (front panel)
Prime Power On/Off
RF Operate/Standby (fault reset)
Operational Status Indicators (front panel)
Prime Power On/Standby
RF Operate
Fault
- Helix Current Overload
- Overtemperature
- Low Line Voltage
- Safety Interlock Open
Metering (front panel)
Helix Current
Protection
Prime Power Fuse (rear panel)
TWT Warm-up Delay
Automatic Sequencing of High Voltage and Beam Current
Unattended Protection (heater shutdown after fault counter trip)
Helix Current Overload
High Temperature
Low Line Voltage
High Line Voltage
Safety Interlocks
AUTOMATIC RECYCLE
The feature automatically recycles the TWTA ready to "RF on" in
the event of a momentary fault condition, such as power outage of
less than 3 seconds, low line voltage, over-temperature, or helix
current overload. In the event of two consecutive helix current
overload faults, the TWTA will revert to the "off" mode and require
manual reset (either locally or via the remote interface) or recycling
the prime power.